CGS electromagnetism: Gaussian, ESU, EMU and Heaviside–Lorentz
Import the catalogue and the explicit electromagnetic conversion entry point:
>>> from unitx.cgs import cgs, gaussian, esu, emu, hl
>>> from unitx.si import si, SI
>>> from fractions import Fraction
>>> (3 * cgs.dyn).to(si.N).value
Fraction(3, 100000)
>>> (3 * cgs.dyn * (2 * cgs.cm)).to(cgs.erg).value
6
>>> cgs.unit('erg/cm') == cgs.erg / cgs.cm
True
>>> (1 * si.J).value_in(cgs.g * cgs.cm**2 / cgs.s**2)
10000000
cgs contains only the shared mechanical units. gaussian inherits cgs and
adds Gaussian electromagnetic units, convert() and formula coefficients.
The esu, emu and hl catalogues offer the same explicit conversion API for
electrostatic, electromagnetic and Heaviside–Lorentz CGS, respectively.
All five are read-only UnitCatalog namespaces with independent parsing environments.
Each electromagnetic parser includes its inherited mechanical definitions.
Pass their Unit objects to ordinary conversions; bare strings keep using the
default environment. Importing the package adds no default spellings.
>>> gaussian.cm is cgs.cm and gaussian.erg is cgs.erg
True
>>> gaussian.unit('erg/statC') == cgs.erg / gaussian.statC
True
>>> hasattr(cgs, 'statC')
False
Exact mechanical units
| Attribute / symbol | Singular name | Definition | Exact SI value |
|---|---|---|---|
cm |
centimetre | shared si.cm |
10⁻² m |
g |
gram | shared si.g |
10⁻³ kg |
s |
second | shared si.s |
s |
Gal |
galileo | shared si.Gal |
10⁻² m/s² |
dyn |
dyne | g cm/s² | 10⁻⁵ N |
erg |
erg | dyn cm | 10⁻⁷ J |
Ba |
barye | dyn/cm² | 10⁻¹ Pa |
P |
poise | dyn s/cm² | 10⁻¹ Pa s |
St |
stokes | cm²/s | 10⁻⁴ m²/s |
New entries accept SI prefixes on their canonical symbol and singular name,
for example cgs.unit('cP'), cgs.unit('cSt') and cgs.unit('millidyne').
They have no additional aliases. Reused SI definitions retain all their existing
spellings and prefix policies, including gal for galileo. cm, g, s and
Gal are the same objects as the SI entries. New definitions retain their own
formal identities. Values agree with the
NIST CGS table.
Base-unit expansion uses an explicit target Unit, as above; there is no automatic unit-system expansion operation.
Gaussian units have mechanical dimensions
The following attributes belong to gaussian; the mechanical catalogue cgs
does not expose or parse them.
| Attribute / symbol | Singular name | Exact definition |
|---|---|---|
statC |
statcoulomb | g^(1/2) cm^(3/2)/s |
statA |
statampere | statC/s |
statV |
statvolt | erg/statC |
statF |
statfarad | statC/statV, equivalent to cm |
G |
gauss | dyn/statC |
Mx |
maxwell | G cm² |
Oe |
oersted | same mechanical scale as G, independent definition |
These entries also accept SI prefixes on their symbols and singular names.
Other historical spellings such as Fr, esu and Gs are not registered.
Rational powers and mechanical factors remain exact.
Module-level definitions support repr/pickle reconstruction after this package is loaded. JSON restoration also requires a receiving Registry that resolves the record's expression with the same definitions:
>>> from unitx import Registry
>>> from unitx.serialization import to_dict, from_dict
>>> receiver = Registry([gaussian.statC, cgs.erg])
>>> from_dict(to_dict(2 * gaussian.statC), registry=receiver) == 2 * gaussian.statC
True
statC and Mx have equal dimensions and factors, as do G and Oe, but each
has a different formal identity. Quantity follows its ordinary numerical rules:
1 * gaussian.statC == 1 * gaussian.Mx is true. A Quantity does not store a physical kind
such as charge or flux. Choosing a conversion kind supplies that interpretation
at the conversion boundary; it cannot check physical kinds throughout a formula.
Explicit SI ↔ Gaussian conversion
gaussian.convert(quantity, target, *, kind=None) accepts a linear Quantity
and a Unit target. Parse strings with the appropriate catalogue first.
>>> charge = gaussian.convert(1.0 * si.C, gaussian.statC)
>>> round(charge.value, 3)
2997924579.802
>>> abs(gaussian.convert(charge, si.C).value - 1) < 1e-15
True
>>> capacitance = gaussian.convert(2 * cgs.cm, si.F, kind='capacitance')
>>> round(capacitance.value * 1e12, 4)
2.2253
Let λ = √kₑ, where kₑ = 1/(4πε₀) is a dimensioned SI quantity. The fixed rule table is:
kind |
SI representative | Gaussian representative | SI → Gaussian multiplier |
|---|---|---|---|
charge |
C | statC | λ |
current |
A | statA | λ |
potential |
V | statV | 1/λ |
electric_field |
V/m | statV/cm | 1/λ |
magnetic_flux_density |
T | G | c/λ |
magnetic_flux |
Wb | Mx | c/λ |
capacitance |
F | statF | λ² |
magnetic_field_strength |
A/m | Oe | 4πλ/c |
The inverse divides by the same multiplier. Explicit kind checks the complete
dimensions of both endpoints, including the logarithmic axis. Either endpoint
may use another unit of the corresponding dimension. No multistep search occurs.
Without kind, the seven named Gaussian representatives in the table select
their own route, including prefixes and additional exact Unit scales. The SI end
may be any unit of the corresponding dimension. Selection uses bound definition
identity, so an independently defined unit called statC does not inherit a route.
Other Gaussian expressions, including statV/cm and a length interpreted as
capacitance, require kind. Formal cancellations that leave a named unit are
recognized normally. With no kind and equal complete dimensions, conversion
uses ordinary linear scaling. An explicit kind always checks both endpoints.
Unknown kind names raise ValueError; unsupported object types raise TypeError. Unmatched routes and incompatible dimensions raise DimensionError. D, P and M, charge/current densities, other circuit quantities and medium constitutive parameters are outside this API. ESU, EMU and Heaviside–Lorentz support the same eight kinds through their own catalogues, as described below.
The result is a new ordinary Quantity. .to(), low-level linear conversion,
equality, hashing, ordering, addition, array assignment and in-place arithmetic
keep their existing dimension rules. For example, (1 * gaussian.statC).to(si.C)
raises DimensionError; convert explicitly before comparing or writing.
ESU, EMU and Heaviside–Lorentz
Each catalogue inherits cgs and supplies convert(quantity, target, *, kind=None)
and em, with the same eight kinds and numerical domains as Gaussian.
Electric ESU units reuse the Gaussian objects; magnetic EMU units reuse the
Gaussian objects. Other definitions have their own formal identities.
| Kind | ESU representative | EMU representative | H–L representative |
|---|---|---|---|
charge |
esu.statC |
emu.abC |
hl.charge |
current |
esu.statA |
emu.abA |
hl.current |
potential |
esu.statV |
emu.abV |
hl.potential |
electric_field |
esu.statV/esu.cm |
emu.abV/emu.cm |
hl.electric_field |
magnetic_flux_density |
esu.magnetic_flux_density |
emu.G |
hl.magnetic_flux_density |
magnetic_flux |
esu.magnetic_flux |
emu.Mx |
hl.magnetic_flux |
capacitance |
esu.statF |
emu.abF |
hl.capacitance |
magnetic_field_strength |
esu.magnetic_field_strength |
emu.Oe |
hl.magnetic_field_strength |
EMU abC is exactly (g*cm)**(1/2), abA = abC/s, abV = erg/abC
and abF = abC/abV. Their singular names are abcoulomb, abampere,
abvolt and abfarad. The ESU magnetic definitions are
dyn*s/(statC*cm), that unit times cm**2, and statA/cm, respectively.
H–L definitions have the same mechanical factors and dimensions as their
Gaussian counterparts; electric and magnetic fields both use dyn**(1/2)/cm.
For parsing, the three ESU magnetic units use the library-specific symbols
esuB, esuFlux, esuH. The H–L symbols are hlC, hlA, hlV, hlE,
hlB, hlFlux, hlF, hlH, in the table's order. These are explicit library
spellings, not claims of standardized historical unit names. All new definitions
accept prefixes on their registered spellings. Named-route inference uses each
catalogue's definitions; the electric-field expressions for ESU and EMU require
kind='electric_field', while the named hl.electric_field can infer it.
>>> esu.statC is gaussian.statC and emu.G is gaussian.G
True
>>> emu.unit('erg/abcoulomb') == emu.erg / emu.abC
True
>>> hl.unit('hlE') == hl.electric_field
True
>>> round(emu.convert(1 * emu.abA, si.A).value, 8)
10.0
>>> q_hl = hl.convert(1.0 * si.C, hl.charge)
>>> import math
>>> math.isclose(q_hl.value / charge.value, math.sqrt(4 * math.pi))
True
The formula coefficients follow Kruger, section II, table II:
| Coefficient | ESU | EMU | H–L |
|---|---|---|---|
k1 |
1 | c² | 1/(4π) |
alpha |
1 | 1 | 1/c |
k2 |
1/c² | 1 | 1/(4πc) |
With the same dimensioned λ = √kₑ as above, the SI → CGS multipliers are:
| Kinds | ESU | EMU | H–L |
|---|---|---|---|
| charge, current | λ | λ/c | √(4π)λ |
| potential, electric field | 1/λ | c/λ | 1/(√(4π)λ) |
| magnetic B, flux | 1/λ | c/λ | c/(√(4π)λ) |
| capacitance | λ² | λ²/c² | 4πλ² |
| magnetic H | 4πλ | 4πλ/c | √(4π)λ/c |
The magnetic H convention also agrees with the Wegner unit-system table,
section 2.b:
in vacuum ESU has H=c**2*B, whereas EMU, Gaussian and H–L have H=B.
For a conducting sphere of radius R, the capacitance is R in ESU/Gaussian,
R/c² in EMU and 4πR in H–L. The factors are dimensioned Quantities, so these
relations work with ordinary unit-aware formulas.
A Quantity stores a magnitude and mechanical Unit, with no electromagnetic
system tag. Equal mechanical dimensions still permit ordinary .to() and
same-dimension convert() scaling, even between different catalogues. That
scaling does not implement physical correspondence between conventions.
To convert an electromagnetic quantity between CGS systems, use SI explicitly:
>>> q_gaussian = 2.0 * gaussian.statC
>>> q_si = gaussian.convert(q_gaussian, si.C)
>>> q_hl = hl.convert(q_si, hl.charge)
>>> math.isclose(q_hl.value, 2 * math.sqrt(4 * math.pi))
True
An explicit kind always checks for one SI endpoint and one endpoint with the chosen CGS dimensions. It rejects a direct CGS-to-CGS correspondence request. With an explicit kind, matching dimensions allow a mechanically equivalent expression or custom unit at the CGS endpoint; its interpretation comes from the selected catalogue and kind, not its spelling or provenance.
Numerical domains and precision
| Operation | Magnitudes | Result domain |
|---|---|---|
| Mechanical / same-dimension scaling | ordinary supported magnitudes | ordinary conversion rules |
| Cross-representation conversion | Python int, float, Fraction | float |
| Cross-representation conversion | Python complex | complex |
| Cross-representation conversion | supported numeric NumPy scalars / plain ndarrays | native NumPy promotion |
| Cross-representation conversion | Decimal, bool, third-party scalar domains | TypeError |
Input arrays are never written. Broadcasting occurs through subsequent ordinary
Quantity arithmetic. Object/bool arrays and unsupported NumPy subclasses retain
the existing rejection rules. No implicit NumPy import occurs on scalar paths.
Static results use Quantity[int | Fraction | float] for real inputs, because
the same-dimension path can remain exact; array results use Quantity[Array],
the NumPy-independent numerical protocol. A particular output dtype is not promised.
The coefficient objects use Python float magnitudes and support the same initial Python/NumPy arithmetic domains. Decimal formulas require separately prepared coefficients and are not supported by these objects.
Mechanical definitions are exact. Physical correspondence uses the library's
CODATA 2022 central value μ₀ = 1.25663706127 × 10⁻⁶ H/m and exact
c = 299792458 m/s, deriving ε₀ = 1/(μ₀c²), kₑ and λ. Constants and π are evaluated
as Python floats. Unit scales and the physical coefficient are combined before
one multiplication of the input magnitude; subsequent rounding and overflow
follow Python/NumPy. This API does not propagate measurement uncertainty.
CODATA 2022 gives μ₀ relative standard
uncertainty 1.6 × 10⁻¹⁰. After the
2019 SI redefinition,
μ₀ is measured, so 1 G ≈ 10⁻⁴ T and 1 Oe ≈ 1000/(4π) A/m are approximate
correspondences here. Historical exact SI-embedded electromagnetic units are
not supplied under the same names.
The mechanical representation and conversion relations were cross-checked against Pint's Gaussian definitions. unitx uses the explicit entry point above and its own limited kind table.
Shared formulas with explicit coefficients
si.em, gaussian.em, esu.em, emu.em and hl.em group read-only k1, alpha, k2 and c
attributes, all ordinary Quantities. These are frozen coefficient objects,
referenced by Final namespace attributes; they are not parsing environments.
k2 = k1/(alpha*c²) is derived; in Gaussian it simplifies to alpha = 1/c.
Here alpha is the Lorentz-force coefficient, unrelated to fine-structure
constant SI.alpha.
The float coefficients are derived from the existing SI constant data. SI
retains its physical constants and their existing numerical domains. si.c is
a speed Unit, while si.em.c is a Quantity representing the same speed.
Choosing either view does not activate a conversion context.
| Coefficient | SI | Gaussian |
|---|---|---|
k1 |
1/(4πε₀) | 1 |
alpha |
1 | 1/c |
k2 |
μ₀/(4π) | 1/c |
>>> def coulomb_force(q1, q2, r, em):
... return em.k1 * q1 * q2 / r**2
>>> q_si, r = 1e-9 * si.C, 2.0 * si.cm
>>> q_g = gaussian.convert(q_si, gaussian.statC)
>>> f_si = coulomb_force(q_si, q_si, r, si.em)
>>> f_g = coulomb_force(q_g, q_g, r, gaussian.em)
>>> import math
>>> math.isclose(f_g.value_in(si.N), f_si.value_in(si.N), rel_tol=2e-15)
True
For the Lorentz force use F = q(E + alpha v × B), with inputs
prepared in the same representation as the coefficients. Vacuum energy density
is E²/(8π k1) + alpha B²/(8π k2); it reduces to (E² + B²)/(8π) in Gaussian.
A sphere's SI capacitance 4πε₀R converts to Gaussian length R via
kind='capacitance'.
No active system or context manager changes existing objects or Python formulas.
There is no separate cgs.constants namespace. Ordinary SI constants can be
converted to mechanical units. For electromagnetic constants, choose a supported
numerical magnitude before mapping; for example, the shipped SI.e uses Decimal:
>>> from unitx import Quantity
>>> electron_charge = gaussian.convert(Quantity(float(SI.e.value), SI.e.unit), gaussian.statC)
>>> round(electron_charge.value * 1e10, 6)
4.803205